BICKER UPSI-2406DP2 – 24V DC UPS with Supercaps – Uninterruptible Power Supply UPS (USV)

Uninterruptible power supply 24V DC UPS with integrated Supercaps (Supercapacitors) Unterbrechungsfreie Stromversorgung 24V DC USV mit integrierten Supercaps BICKER UPSI-2406DP2 / 96W / 24V 4A / DIN Rail Chapters: 0:00 Intro 0:16 UPSI-2406DP2 - 24V DC UPS system 0:38 Power Failures, flicker and voltage fluctuations 0:50 Intelligent power sharing (Input/Output/Charger) 1:07 Communication interfaces USB/RS232 1:14 UPScom software 1:32 Integrated Supercap buffering 1:52 Outro --- More information: https://www.bicker.de/en/upsi-2406dp2 --- /// Safe protection against blackout & grid failures! Avoid costly system downtimes and data loss! The new DC-UPS UPSI-2406DP2 with integrated Supercap buffering reliably bridges power failures and faults, so that the uninterruptible 24 VDC power supply is ensured at the output. Due to optimized power electronics, DC loads of up to 100 Watt can be safely bridged.Power failures, voltage drops, fluctuations and flicker in the 24 VDC supply network can quickly become a problem in production systems, safety technology and embedded industrial PCs and cause costly failures or even data loss. The intelligent emergency power supply UPSI-2406DP2 with Supercaps ensures the fail-safe supply of the connected DC load. Equipped with numerous additional functions, our DC UPS solutions convince in a wide variety of applications worldwide!The compact DC UPS modules in a robust DIN rail housing are ideally suited for long-term use in control cabinet applications and decentralized solutions for protecting embedded industrial PCs, controls, motor drives, sensors, measurement devices, safety technology and many more. /// Long-life Supercaps – maintenance-free energy storage For uninterruptible DC power supplies, there are absolutely maintenance-free long-life Supercaps (ultra-capacitors) available as highly efficient and particularly long-lasting energy storage devices with up to 500,000 charge and discharge cycles in the area of short and medium bridging times. In contrast to batteries, which store energy via a detour through a chemical reaction, supercaps are based on electrophysical principles and are charged and ready for use within a very short time. Under comparable operating conditions, supercaps have a service life that is up to ten times longer than that of classic lead-acid batteries. Energy storage systems with Supercapacitors also impress with their high current carrying capacity, power density and reliability. The long-life Supercap energy storage of the UPSI-2406DP2 works in the extended temperature range and has integrated cell balancing. /// 'Power Sharing' with intelligent input current detection The intelligent PowerSharing at 24VDC input ensures that the upstream AC/DC power supply does not have to be overdimensioned, because the input power is kept constant and appropriately distributed to load and Li-Ion battery charger. With a low load at the output, more energy flows into the charger and vice versa. This saves energy and costs. /// Minimum load detectionWith help of the integrated load sensor, the DC UPS is switched off as soon as the load value falls below the threshold (no load) so that energy is not used unnecessarily. /// Plug&Play for quick and easy installation The DC UPS module has an integrated USB interface for connection to an IPC system. The UPSI-2406DP1 is recognized directly by the operating system as an UPS - without additional driver or software installation. /// Pre-programmable for self-sufficient operationThe included software "UPS Gen2 Configuration" can be downloaded free of charge for setting and preprogramming all parameters of the DC UPS system and for real-time monitoring with fuel gauge. The adjustable parameters include load sensor (mA), shutdown delay, maximum backup time, minimum battery capacity before power up, ignition timer and restart delay. The data connection to the IPC system takes place via integrated USB interface. /// Shutdown & Reboot function for IPC systemsIn the event of a "PowerFail", the DC UPS signals the failure via the integrated interface, so that a controlled shutdown of the computer system is initiated and valuable data can be saved. The integrated reboot function of the DC UPS automatically initiates the restart of the supplied IPC after the supply voltage has returned, without the need for costly on-site intervention by a service employee, e.g. with completely self-sufficient computer systems in inaccessible locations. /// Tested according to IEC/UL/CSA 61010-1 / -2-201The DC UPS system UPSI-2406DP2 has international safety certifications for worldwide use: ETL UL61010-1 / -2-201, CSA C22.2 61010-1-12 / -2-201, CB Scheme IEC 61010-1 /-2-201.

Filtern

Suchbegriff

Unterkategorie

Firmen

Inhaltstyp

Firmentyp

Land