Bicker upsi-2406dp3 – 24v dc ups with lifepo4 battery – uninterruptible power supply ups (usv)

Uninterruptible power supply 24V DC UPS with integrated LiFePO4 lithium iron phosphate battery Unterbrechungsfreie Stromversorgung 24V DC USV mit integrierter LiFePO4 Lithium-Eisen-Phosphat Batterie BICKER UPSI-2406DP3 / 96W / 24V 4A / DIN Rail Chapters: 0:00 Intro 0:16 UPSI-2406DP3 - 24V DC UPS system 0:38 Power Failures, flicker and voltage fluctuations 0:50 Intelligent power sharing (Input/Output/Charger) 1:07 Communication interfaces USB/RS232 1:14 UPScom software 1:32 Integrated LiFePO4 battery pack 1:53 Outro --- More information: https://www.bicker.de/en/upsi-2406dp3 --- /// Safe protection against blackout & grid failures! Avoid costly system downtimes and data loss! The new DC-UPS UPSI-2406DP3 with integrated LiFePO4 battery reliably bridges power failures and faults, so that the uninterruptible 24 VDC power supply is ensured at the output. Due to optimized power electronics, DC loads of up to 100 Watt can be safely bridged.Power failures, voltage drops, fluctuations and flicker in the 24 VDC supply network can quickly become a problem in production systems, safety technology and embedded industrial PCs and cause costly failures or even data loss. The intelligent emergency power supply UPSI-2406DP3 with integrated Li-Ion battery ensures the fail-safe supply of the connected DC load. Equipped with numerous additional functions, our DC UPS solutions convince in a wide variety of applications worldwide!The compact DC UPS modules in a robust DIN rail housing are ideally suited for long-term use in control cabinet applications and decentralized solutions for protecting embedded industrial PCs, controls, motor drives, sensors, measurement devices, safety technology and many more. /// What are the advantages of LiFePO4 technology? As DC UPS energy storage for longer hold-up times, lithium-ion technology with a high energy density is ideal. When selecting a safe Li-ion battery pack, a closer look at the used cathode material is recommended. With lithium-iron phosphate (LiFePO4), a very stable chemical compound with increased safety and a ten times higher cycle stability (6,000 charging and discharging cycles) compared to conventional Li-ion cells (LCO/NMC) is available. The high-quality LiFePO4 battery packs Bicker BP-LFP (heat shrink tube) and BP-LFP-D (DIN rail) also have a integrated high-performance battery management system (BMS) to optimize service life and security. The BMS monitors and controls the complete charge and discharge process of each energy storage battery cell. The integrated cell-balancing ensures a balanced and even charge of all cells, so that the full capacity of the lithium-ion battery pack remains permanently usable. /// 'Power Sharing' with intelligent input current detection The intelligent PowerSharing at 24VDC input ensures that the upstream AC/DC power supply does not have to be overdimensioned, because the input power is kept constant and appropriately distributed to load and Li-Ion battery charger. With a low load at the output, more energy flows into the charger and vice versa. This saves energy and costs. /// 'Smart Battery Lock' prevents battery discharge The battery management system prevents the integrated battery pack from leakage discharging when the UPSI-2406DP3 is switched off by deactivating the battery accordingly. By reducing the BMS own power consumption to a minimum, safety and shelf life of the DC UPS also increases significantly. With help of the integrated load sensor, the DC UPS is switched off as soon as the load value falls below the threshold (no load) so that energy is not used unnecessarily. /// Plug&Play for quick and easy installation The DC UPS module has an integrated USB interface for connection to an IPC system. The UPSI-2406DP3 is recognized directly by the operating system as an UPS - without additional driver or software installation. /// Pre-programmable for self-sufficient operation The included software "UPS Gen2 Configuration" can be downloaded free of charge for setting and preprogramming all parameters of the DC UPS system and for real-time monitoring with fuel gauge. The adjustable parameters include load sensor (mA), shutdown delay, maximum backup time, minimum battery capacity before power up, ignition timer and restart delay. The data connection to the IPC system takes place via integrated USB interface. /// Shutdown & Reboot function for IPC systems In the event of a "PowerFail", the DC UPS signals the failure via the integrated interface, so that a controlled shutdown of the computer system is initiated and valuable data can be saved. The integrated reboot function of the DC UPS automatically initiates the restart of the supplied IPC after the supply voltage has returned, without the need for costly on-site intervention by a service employee, e.g. with completely self-sufficient computer systems in inaccessible locations.

Filtern

Suchbegriff

Unterkategorie

Firmen

Inhaltstyp

Firmentyp

Land